39- 6
Control/computer equipment – 8700
Function for program downloading
T-code
403-414, 669-671, 716-718
Date
2005-06-01
39.6.1 Normal loading
Select Open.. to open the file to be downloaded to a node. File name,
file type and version number are shown in the " file information" box. If it
is a file for checks, specify the type of checks that are to receive the file.
Start loading by selecting Start... and restart the truck by entering the
driver PIN-code and then pressing the green button on the keypad.
Restart must take place within 20 of the Start button being activated.
Close the loading box once loading is intact and then disconnect the PC
from the network. A new connection can now be made to verify the new
program.
39.6.2 Loading in old versions of the
electronic card
If loading is to take place to an older type of electronics card which does
not support restart with a key, the Old card button... must be used
instead of Start...
Loading takes place in the same way, except restart takes place by
using the battery plug instead of the key.
39.6.3 Emergency loading
If for any reason there is no program in the electronics card (interrupted
loading) E141 will be displayed on the truck display at start. The com-
munication with the truck via the PC will then be minimised. Use "E141"
to download the program to the card.
On certain trucks, there is a counter on the display which continuously
counts up.
NOTE!
The electronic cards for certain trucks can only be upgraded with the
same basic program once they have been programmed. It is therefore
not possible to change the basic program (other machine type).