© BT Europe AB
Electronic card – 5710
Error Codes
Valid from serial number
713962-
Order number
218920-040
Code
Description
Error mode
Error cause
Comments
1. Replace the drive regulator, A1..
Code
Description
Error mode
Error cause
Comments
Temperature sensor B1 in drive motor M1
1. Check that the ventilation is okay, especially the fan M10 in the
motor compartment.
2. Check B1.
- Remove connection X26. Measure B1 in X26 with the ohmmeter,
approx. 570 ohm at 20
- Check that cable 11 is intact between X26 and terminal 4 on A1.
- Check that cable 14 is intact between X26 and terminal 7 on A1.
- Also check the connector pins on the terminals for play and oxidi-
sation.
Service Manual
https://www.forkliftpdfmanuals.com/
203
CPU or memory fault on the drive regulator
Drive regulator error
1. Defective drive regulator
205
Overheated drive motor
Drive regulator error
1. Motor overloaded
2. Defective cabling/temperature sensor
Restart possible
o
C.
REFLEX RR B/E, RR B/E CC
T-code
403-414, 669-671, 716-718
Date
2005-06-01
24- 89