18. IR Remote Controller (REMC3)
18.1. Overview
The REMC3 circuit generates infrared remote control output signals. This circuit can also be applicable
to an EL lamp drive circuit by adding a simple external circuit.
The features of the REMC3 are listed below.
Outputs an infrared remote control signal.
Includes a carrier generator.
Flexible carrier signal generation and data pulse width modulation.
Automatic data setting function for continuous data transmission.
Output signal inverting function supporting various formats.
EL lamp drive waveform can be generated for an application example.
Figure 18.1.1 shows the REMC3 configuration.
Item
Number of channels
Clock
generator
CPU core
S1C31D50 TECHNICAL MANUAL
(Rev. 1.00)
Table 18.1.1 REMC3 Channel Configuration of S1C31D50
REMC3
CLKSRC[1:0]
Carrier signal
CLKDIV[3:0]
DBRUN
MODEN
Data signal
DBLENBSY
APLENBSY
REMCRST
DBCNT[15:0]
DBCNTRUN
control circuit
DBIE
APIE
Figure 18.1.1 REMC3 Configuration
Seiko Epson Corporation
S1C31D50
1 transmitter channel
CRPER[7:0]
CRDTY[7:0]
CARREN
generator
PRESET
PRUN
DBLEN[15:0]
APLEN[15:0]
BUFEN
REMOINV
generator
OUTINVEN
TRMD
Interrupt
DBIF
APIF
REMO
CLPLS
18-1