DIGITAL DIAGNOSTIC MONITORING COMMANDS

The Digital Diagnostic Monitoring (DDM) commands in the Command Line Interface (CLI) are listed (along with
the appropriate parameters) in the following table.
Command

config ddm ports

config ddm power_unit
show ddm ports
Each command is listed in detail, as follows:
config ddm ports
Purpose
Syntax
Description
Parameters
Restrictions
Example usage:
DGS-1210/ME Metro Ethernet Switch CLI Reference Guide
Parameter
<portlist> [bias_current_threshold [high_alarm | low_alarm] | rx_power_threshold
| shutdown | state [enable | disable] | temperature_threshold |
tx_power_threshold | voltage_threshold]
[mw | dbm]
<portlist> [configuration | status | vendor_info]
To configure the DDM settings of the specified ports.
config ddm ports <portlist> [bias_current_threshold
[high_alarm | low_alarm] | rx_power_threshold | shutdown |
state [enable | disable] | temperature_threshold |
tx_power_threshold | voltage_threshold]
The config ddm ports command is used to configure the DDM
settings of the specified ports.
<portlist> - Specifies the range of ports to be configured.
bias_current_threshold - Specify the threshold of the optic module's
bias current.
high_alarm - Specify the high threshold for the alarm. When the
operating parameter rises above this value, the action associated
with the alarm is taken.
low_alarm -Specify the low threshold for the alarm. When the
operating parameter falls below this value, the action associated
with the alarm is taken.
rx_power_threshold - Specify the threshold of optic module's
received power.
state - Specify the DDM state to enable or disable. If the state is
disabled, no DDM action will take effect.
temperature_threshold - Specify the threshold of the optic module's
temperature in centigrade. At least one parameter shall be specified
for this threshold.
shutdown - Specify whether or not to shutdown the port when the
operating parameter exceeds the corresponding alarm threshold or
warning threshold. The default value is none.
tx_power_threshold - Specify the threshold of the optic module's
output power.
voltage_threshold - Specify the threshold of optic module's voltage.
Only Administrator or operator-level users can issue this command.