Show Power_Saving - D-Link DGS-1210/ME Series Reference Manual

Metro ethernet switches
Hide thumbs Also See for DGS-1210/ME Series:
Table of Contents

Advertisement

Description
Parameters
Restrictions
Example usage:
To configure the power saving on the switch:
DGS-1210-28MP/ME:5# config power_saving mode port hibernation enable
Command: config power_saving mode port hibernation enable
Success.
DGS-1210-28MP/ME:5#

show power_saving

Purpose
Syntax
Description
Parameters
Restrictions
Example usage:
To display power saving information on the switch:
DGS-1210-28MP/ME:5# show power_saving length_detection
Command: show power_saving length_detection
Length Detection State : Enabled
DGS-1210-28MP/ME:5#
DGS-1210/ME Metro Ethernet Switch CLI Reference Guide
| <portlist>]] [add | delete] time_range1 <range_name 20>
time_range2 <range_name 20> {clear_time_range}
The config power_saving command is used to configure the power
saving on the switch.
hibernation – Configure the hibernation.
led [all | <portlist>] – Configure the ports for led.
port – Configure ports.
[add | delete] – Add or delete time range for power saving mode.
time_range1 <range_name 20> – Specifies the time range 1 to be
configured.
time_range2 <range_name 20> – Specifies the time range 2 to be
configured.
{clear_time_range} – Clear the time range setting for power saving
on the Switch.
Only Administrator or operator–level users can issue this command.
To display power saving information on the switch.
show power_saving {hibernation | led | length_detection | port |
link_detection}
The show power_saving is used to display power saving
information.
hibernation – Display the hibernation state.
led – Display the led state.
length_detection – Display the length detection state.
port – Display ports state.
link_detection – Display link detection state.
None.
149

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents