To specify the ring-port to be east for ERPS instance ID 1:
DGS-1210-28MP/ME:5# erps manual switch instance 1 ring_port east
Command: erps manual switch instance 1 ring_port east
Success.
DGS-1210-28MP/ME:5#

config erps version

Purpose
Syntax
Description
Parameters
Restrictions
Example usage:
To specify the ERPS version:
DGS-1210-28MP/ME:5# config erps version g.8032v2
Command: config erps version g.8032v2
Success.
DGS-1210-28MP/ME:5#
DGS-1210/ME Metro Ethernet Switch CLI Reference Guide
Used to specify the ERPs version on the switch.
config erps version {g.8032v1 | g.8032v2}
The config erps version is used to specify the ERPS version on the
switch.
{g.8032v1 | g.8032v2} – Specify to use the G.8032v1 or G.8032v2
ERP version. By default, G.8032v2 is used.
G.8032v2 fully provides the following enhanced functions:
Supports multi-instance in a physical ring.
Supports operation commands: manual, force, and clear
Support the configuration of the sending of a R-APS PDU
destination address with the physical ring's ring ID.
Before specifying G.8032v1 for a G.8032v2 device, changing the
ERPS version will lead to the restart of the running protocol.
If Ethernet ring nodes running ITU-T G.8032v1 and ITU-T G.8032v2
co-exist on an Ethernet ring, the following configurations should be
met on the G.8032v2 device:
All physical ring IDs have the default value of 1.
Interconnection node 's major ring and sub-ring instances must
have different R-APS VIDs.
Manual switch or force switch commands not exist.
Physical rings have only one instance.
Only Administrator, operator and power user-level users can issue
this command.