Description
Parameters
Restrictions
Example usage:
To configure the ring MEL of ERPS RAPS:
DGS-1210-28MP/ME:5# config erps raps_vlan 1 ring_mel 1
Command: config erps raps_vlan 1 ring_mel 1
Success.
DGS-1210-28MP/ME:5#

config erps raps_vlan ring_port

Purpose
Syntax
Description
Parameters
DGS-1210/ME Metro Ethernet Switch CLI Reference Guide
The config erps raps_vlan ring_mel is used to configure the ring
MEL for an R-APS VLAN.
The ring MEL is one field in the R-APS PDU. Note that if CFM
(Connectivity Fault Management) and ERPS are used at the same
time, R-APS PDU is one of a suite of Ethernet OAM PDU. The
behavior for forwarding of R-APS PDU should follow the Ethernet
OAM. If the ring MEL is not higher than the highest MEL of the
MEPs on the ring ports, the R-APS PDU cannot be forwarded on the
ring.
<vlanid 1-4094> - Specify the VLAN ID to be configured.
ring_mel <value 0-7> – Specifies the ring MEL of the R-APS
function. The value is between 0 and 7. The default ring MEL is 1.
Only Administrator, operator and power user-level users can issue
this command.
Used to configure the ports of the ERPS ring for a specific R-APS
VLAN.
config erps raps_vlan <vlanid 1-4094> ring_port [west [<port> |
virtual_channel] | east [<port> | virtual_channel]]
The config erps raps_vlan ring_port is used to configure the port
that participates in the ERPS ring.
Restrictions apply for ports that are included in a link aggregation
group. A link aggregation group can be configured as a ring port by
specifying the master port of the link aggregation port. Only the
master port can be specified as a ring port. If the specified link
aggregation group is eliminated, the master port retains its ring port
status. If the ring port is configured on a virtual channel, the ring that
the port is connected to will be considered as a sub-ring.
Note that modifying the ring port number may not take effect
immediately when ERPS function is enabled. The ring will run the
old configuration's protocol if the follow conditions are not met:
The Ring port is a tagged member port of the R-APS VLAN.
The RPL port is not virtual channel.
The Ring port is the master port if it belongs to a link aggregation
group.
<vlanid 1-4094> - Specify the VLAN ID to be configured.
west [<port> | virtual_channel] – Specifies a port as the west ring
port or a west port on the virtual channel.
east [<port> | virtual_channel] – Specifies a port as the east ring port
237