Config Loopdetect; Show Loopdetect - D-Link DGS-1210/ME Series Reference Manual

Metro ethernet switches
Hide thumbs Also See for DGS-1210/ME Series:
Table of Contents

Advertisement

Success.
DGS-1210-28MP/ME:5#

config loopdetect

Purpose
Syntax
Description
Parameters
Restrictions
Example usage:
To configure the loop back detection with interval time 500 on the Switch:
DGS-1210-28MP/ME:5# config loopdetect interval_time 500
Command: config loopdetect interval_time 500
Success.
DGS-1210-28MP/ME:5#

show loopdetect

Purpose
Syntax
Description
Parameters
Restrictions
Example usage:
To display the loop back detection information on the Switch:
DGS-1210-28MP/ME:5# show loopdetect
Command: show loopdetect
Loopdetect Global Settings
--------------------------------------------
Loopdetect Status
Loopdetect Mode
DGS-1210 Metro Ethernet Managed Switch CLI Reference Guide
To configure the loop back detection interval time and recover time
on the Switch.
config loopdetect interval_time <value 1-32767>
lbd_recover_time [0 | <value 60-1000000>]
The config loopdetect command configures the loop back
detection interval time and recover time on the Switch.
interval_time <value 1-32767> − Specifies the interval time of loop
back detection. The range is between 1 and 32767 seconds.
lbd_recover_time [0 | <value 60-10000>] − Specifies the recover
time of loop back detection on the switch. The range is between 60
and 10000 seconds.
Only administrator-level users can issue this command.
To display the loop back detection information on the Switch.
show loopdetect {ports [<portlist> | all]}
The show loopdetect command displays the loop back detection
information on the Switch.
<portlist> − A port or range of ports to be displayed.
all − All ports settings are to be displayed.
None.
: Enabled
: Port-Base
56

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents