Thermal Events (800 Through 899) - HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual

Fw v06.xx/hafm sw v08.02.00 hp storageworks edge switch 2/24 service manual (aa-rtdxc-te, july 2004)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Event Codes

Thermal Events (800 through 899)

Table 106: Event Code 810
Message:
High temperature warning (CTP card thermal sensor).
Severity:
Major.
Explanation:
The thermal sensor associated with a CTP card indicates the warm temperature
threshold was reached or exceeded.
Action:
Replace the failed switch. Perform the data collection procedure and return the
backup disk and faulty switch to Hewlett-Packard support personnel.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
EWS
Event
Log
Table 107: Event Code 811
Message:
Critically hot temperature warning (CTP card thermal sensor).
Severity:
Major.
Explanation:
The thermal sensor associated with a CTP card indicates the hot temperature
threshold was reached or exceeded.
Action:
Replace the failed switch. Perform the data collection procedure and return the
backup disk and faulty switch to Hewlett-Packard support personnel.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
EWS
Event
Log
298
HAFM Appliance
System
Event
Error
Log
Indicator
HAFM Appliance
System
Event
Error
Log
LED
E-Mail
Call
Home
E-Mail
Call
Home
Edge Switch 2/24 Service Manual
Host
Sense
Link
Info
Incident
Host
Sense
Link
Info
Incident

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks edge switch 2/32

Table of Contents