12
A 070 event code indicates an E_Port detected an incompatibility with an attached
switch and prevented the switches from forming a multiswitch fabric. A segmented
E_Port cannot transmit Class 2 or Class 3 Fibre Channel traffic.
A 071 event code indicates the switch is isolated from all switches in a multiswitch
fabric, and is accompanied by a 070 event code for each segmented E_Port. The 071
event code is resolved when all 070 events are corrected.
Obtain supplementary event data for each 070 event code.
a. At the Hardware View, click Logs and select Event Log. The Event Log
displays.
b. Examine the first five bytes (0 through 4) of event data.
c. Byte 0 specifies the switch port number (00 through 139) of the segmented
E_Port. Byte 4 specifies the segmentation reason
Table 2–16: Byte 4, Segmentation Reasons, and Actions
Byte 4
01
02
03
04
05
06
07
13
As indicated by an event code 072, a switch E_Port is connected to an unsupported
switch or fabric element.
Advise the customer of the problem and disconnect the interswitch link to the
unsupported switch. Exit MAP.
edge switch 2/24 service manual
Segmentation Reason
Incompatible operating
parameters.
Duplicate domain IDs.
Incompatible zoning
configurations.
Build fabric protocol error.
No principal switch.
No response from attached
switch.
ELP retransmission failure
timeout.
(Table
2–16).
Action
Go to
step
14.
Go to
step
15.
Go to
step
16.
Go to
step
17.
Go to
step
19.
Go to
step
20.
Go to
step
21.
Diagnostics
2–83

Advertisement

Table of Contents
loading

Table of Contents