Display Fic Alarms; Display The Fic Status; Display Fic Errors In The Messages Log File - Juniper M Series Monitoring And Troubleshooting Manual

Hide thumbs Also See for M Series:
Table of Contents

Advertisement

Related
Documentation

Display FIC Alarms

Display the FIC Status

Purpose
Action
Sample Output
Meaning

Display FIC Errors In the messages Log File

Purpose
Action
Sample Output
Meaning
Copyright © 2012, Juniper Networks, Inc.
Checklist for Monitoring the FIC on page 543
To determine whether the FIC is offline:
Display the FIC Status on page 547
1.
Display FIC Errors In the messages Log File on page 547
2.
Display FIC Errors In the chassisd Log File on page 548
3.
To display the FIC status.
To view the FIC status, use the following command:
user@host> show chassis pic pic-slot 3 fpc-slot 1
user@host> show chassis pic pic-slot 3 fpc-slot 1
PIC fpc slot 1 pic slot 3 information:
State
The FIC in
fpc slot 1 pic slot 3
To determine the details of the FIC error messages in the messages log file.
To display the FIC errors recorded in the
user@host> show log messages | match PIC 3
user@host> show log messages | match PIC 3 in FPC 1
Feb 22 05:50:58
noah chassisd[4738]: CHASSISD_PIC_OFFLINE_NOTICE: Taking PIC 3
in FPC 1 offline: Offlined by cli command
Feb 22 05:50:58
noah cfeb CMFPC: Offline CMD request for PIC 1/3
Feb 22 05:50:58
noah chassisd[4738]: CHASSISD_IFDEV_DETACH_PIC:
ifdev_detach_pic(1/3)
Feb 22 05:50:58
noah chassisd[4738]: CHASSISD_SNMP_TRAP9: SNMP trap generated:
FRU power off (jnxFruContentsIndex 8, jnxFruL1Index 2, jnxFruL2Index 4,
jnxFruL3Index 0, jnxFruName PIC: 2x F/E, 100 BASE-TX @ 1/3/*, jnxFruType 11,
jnxFruSlot 2, jnxFruOfflineReason 7, jnxFruLastPowerOff 30713054, jnxFruLastPowerOn
407915)
The
messages
log file records the error events during the time the FIC went offline. The
log file records the time and date and the SNMP trap message generated.
messages
Offline
is offline.
log file, use the following command:
messages
Chapter 26: Monitoring the FIC