Table 34: T1600 Router Chassis Component Alarm Conditions (continued)
Chassis
Component
Alarm Condition
Alternative media
The router boots from
alternate boot device, the
hard disk. Typically, the router
boots from the flash drive. If
you configure your router to
boot from the hard disk, ignore
this alarm condition.
Control Board
A Control Board was removed.
A Control Board temperature
sensor alarm has failed.
A Control Board failed.
CIP
A CIP is missing.
Craft interface
The craft interface failed.
Fan trays
One fan tray was removed
from the chassis.
Two or more fan trays were
removed from the chassis.
One fan in the chassis is not
spinning or is spinning below
the required speed.
Chapter 3: Method and Tools for Monitoring Router Components
Remedy
For technical support,
open a support case
using the Case Manager
link at
http://www.juniper.net
/support/
or call
1-888-314-JTAC (within
the United States) or
1-408-745-9500
(outside the United
States).
Insert a Control Board
into an empty slot.
Replace the failed
Control Board.
Replace the failed
Control Board.
Insert a CIP into an
empty slot.
Replace the failed craft
interface.
Install the missing fan
tray.
Install the missing fan
trays.
Replace the fan tray.
Alarm
Severity
Yellow
Yellow
Yellow
Red
Red
Red
Yellow
Red
Red
103