Table 162: Hcm Leds - Juniper M Series Monitoring And Troubleshooting Manual

Hide thumbs Also See for M Series:
Table of Contents

Advertisement

M Series and T Series Routers Monitoring and Troubleshooting Guide
Check the HCM Environmental Status
Purpose
Action
Sample Output
Meaning
Related
Documentation
Switch HCM Mastership
738

Table 162: HCM LEDs

Label
Color
PWR
Green
MSTR
Blue
To determine HCM mastership by checking the HCM environmental status.
To check the HCM environmental status and view which HCM is functioning as master,
use the following command:
user@host>show chassis environment hcm
user@host> show chassis environment hcm
HCM 0 status:
State
FPGA Revision
HCM 1 status:
State
FPGA Revision
The command output shows that both HCMs (HCM0 and HCM1) are online. HCM0 is
functioning as master, and HCM1 is functioning as standby. The command output also
gives the Field Programmable Gate Array (FPGA) revision level. The FPGA is a gate on
the chip used in the HCM.
Checklist for Monitoring Redundant HCMs on page 735
When HCM mastership changes because of failure, Routing Engine mastership will change
as well.
If the Routing Engines are running Junos OS Release 6.0 or later and are configured for
graceful switchover, the standby Routing Engine immediately assumes Routing Engine
functions and there is no interruption to packet forwarding. Otherwise, packet forwarding
halts while the standby Routing Engine becomes the master and the Packet Forwarding
Engine components reset and connect to the new master Routing Engine. For information
about configuring graceful switchover, see the section about Routing Engine redundancy
in the Junos OS System Basics Configuration Guide.
State
Description
On steadily
HCM is functioning normally.
Blinking
HCM is starting up.
On steadily
HCM is master.
Online Master
27
Online Standby
27
Copyright © 2012, Juniper Networks, Inc.