Figure 129: M20 Router Power Supplies - Juniper M Series Monitoring And Troubleshooting Manual

Hide thumbs Also See for M Series:
Table of Contents

Advertisement

M Series and T Series Routers Monitoring and Troubleshooting Guide
Related
Documentation
M40 Router Power Supplies
280
NOTE:
Mixing AC and DC power supplies is not supported. The two power
supplies must be either both AC or both DC.
When two power supplies are installed, at least one Routing Engine and one
FPC must also be installed for both power supplies to power on. In the
absence of this minimum load, only one power supply starts. (The router
powers and on and operates correctly with one power supply, but without
the redundancy benefit of having a second power supply installed.)

Figure 129: M20 Router Power Supplies

M20 router rear
Power supply A
Power supply B
Checklist for Monitoring Power Supplies on page 273
The M40 router can use either AC or DC power. Two load-sharing power supplies install
into the bays located at the bottom rear of the chassis. As viewed from the rear of the
chassis, the supply on the left is referred to as supply
supply
.
Figure 130 on page 281
B
are installed in the chassis.
The power supplies are fully redundant. When both power supplies are operational, they
automatically share the electrical load. If one power supply stops functioning for any
reason, the remaining power supply instantly begins providing all the power the router
needs for normal functioning, and can provide full power indefinitely.
DC power supply
AC power supply
and the supply on the right as
A
shows the M40 router power supplies and where they
Copyright © 2012, Juniper Networks, Inc.