Sample Output
Meaning

Display the CFEB Detailed Status

Purpose
Action
Sample Output
Meaning
Check CFEB LEDs
Purpose
522
user@host> show chassis environment
user@m5-host> show chassis environment
Class Item
Power Power Supply 0
Power Supply 1
Temp
Intake
FPC 0
Power Supplies
CFEB Intake
CFEB Exhaust
[...Output truncated...]
The command output displays the temperature and status of the CFEB intake and
exhaust, which can be
,
OK
To obtain a more detailed status of the CFEB.
To display more detailed CFEB status, use the following command:
user@host> show chassis cfeb
user@host> show chassis cfeb
CFEB status:
Slot 0 information:
State
Intake temperature
Exhaust temperature
CPU utilization
Interrupt utilization
Heap utilization
Buffer utilization
Total CPU DRAM
Internet Processor II
Start time:
Uptime:
Slot 1 information:
State
The command output displays the temperature of the air passing by the CFEB intake
and exhaust, in degrees Centigrade. It displays the total percentage of CPU, interrupt,
heap space, and buffer space being used by the CFEB processor, including the total DRAM
available to the CFEB processor. The command output displays the time when the CFEB
started running and how long the CFEB has been running. A short uptime can indicate
that there is a CFEB problem.
Three LEDs—a green LED labeled
MASTER
—indicate CFEB status.
Status
Measurement
OK
Absent
OK
22 degrees C / 71 degrees F
OK
23 degrees C / 73 degrees F
OK
23 degrees C / 73 degrees F
OK
24 degrees C / 75 degrees F
OK
30 degrees C / 86 degrees F
, or
.
Failed
Absent
Master
29 degrees C / 84 degrees F
38 degrees C / 100 degrees F
3 percent
0 percent
10 percent
22 percent
128 MB
Version 1, Foundry IBM, Part number 164
2004-09-28 03:07:54 PDT
9 days, 18 hours, 36 minutes, 15 seconds
Backup
, a red LED labeled
OK
, and a blue LED labeled
FAIL
Copyright © 2012, Juniper Networks, Inc.