M5 and M10 Router Cooling Systems

Figure 154: M5 and M10 Router Cooling System and Airflow

Related
Documentation
M7i Router Cooling System
320
Checklist for Monitoring the Cooling System on page 317
The M5 and M10 router houses four fans, which draw room air into the chassis to keep
the internal temperature below a maximum acceptable level. The air flows side-to-side
in the chassis (see
Figure 154 on page
CAUTION:
Do not remove the fan tray for more than one minute while the
router is operating. The fans are the sole source of cooling, and the router
can overheat when they are absent.
Checklist for Monitoring the Cooling System on page 317
The M7i router cooling system consists of a fan tray, located along the left side of the
chassis, that provides side-to-side cooling. It connects directly to the router midplane.
The fan tray is a single unit containing four individually fault-tolerant fans. If a single fan
fails, the remaining fans continue to function indefinitely.
The cooling system draws in room air through the air intake vent on the left side of the
chassis. After entering the chassis, the air stream separates into separate flows for the
front and rear components (see
320).
Figure 155 on page
321).