Figure 287: Redundancy Connection For An M10I Router; Redundancy Connection For An M20 Router - Juniper M Series Monitoring And Troubleshooting Manual

Hide thumbs Also See for M Series:
Table of Contents

Advertisement

Related
Documentation
Redundancy Connection for an M10i Router
Related
Documentation

Redundancy Connection for an M20 Router

Copyright © 2012, Juniper Networks, Inc.
should happen. For example, you can use the
statement at the [
other-routing-engine
failover for the interface control daemon.
Checklist for Host Redundancy on page 563
Figure 287 on page 571
shows the connection between the master and backup Routing
Engines on an M10i router. Keepalive messages are sent between Routing Engines via
the interconnected HCM switches. In this way, the master and the backup Routing Engines
exchange state information.

Figure 287: Redundancy Connection for an M10i Router

Master Routing Engine
RE0
FXP1
HCM0
Switch
keepalive messages
physical connection
M10i Router Redundant Routing Engines and HCMs on page 566
Figure 288 on page 572
shows the connection between the master and backup Routing
Engines on an M20 router. Keepalive messages are sent between the master and backup
Routing Engine through the switch on the SSB. In this way, the master and the backup
Routing Engines exchange state information.
Chapter 28: Host Redundancy Overview
set interface-control failover
] hierarchy level to configure
edit system processes
Backup Routing Engine
FXP1
Switch
RE1
HCM1
571