Displaying Fpc Error Messages In The Chassis Daemon Log File - Juniper M Series Monitoring And Troubleshooting Manual

Hide thumbs Also See for M Series:
Table of Contents

Advertisement

M Series and T Series Routers Monitoring and Troubleshooting Guide
Meaning

Displaying FPC Error Messages in the Chassis Daemon Log File

Purpose
Action
Sample Output
222
Mar 10 09:20:37 cls-edge-02 ssb CM(0): Slot 1: Unrecoverable error; probe failed
Mar 10 09:20:37 cls-edge-02 ssb CM(0): Slot 1: Too many unrecoverable errors,
going off-line
Mar 10 09:20:37 cls-edge-02 ssb CM(0): ALARM SET: (Major) Slot 1: Too many
unrecoverable errors
Mar 10 09:20:37 cls-edge-02 ssb CM(0): Slot 1: Off-line
Mar 10 09:20:38 cls-edge-02 ssb PFEMAN: FPC socket closure indicated
Mar 10 09:20:38 cls-edge-02 ssb PFEMAN: closing FPC 1 socket
Mar 10 09:20:42 cls-edge-02 ssb PFEMAN: FPC socket closure indicated
Mar 10 09:20:42 cls-edge-02 ssb PFEMAN: close on unlisted socket, 0xb0e200
The following output displays when you use the
information in the
messages
user@host>
show log messages | match fpc
Mar 31 05:07:58 bopper fpc6 D4-6/0 AMCC: Transmitter laser bias out of range.
Mar 31 05:08:37 bopper chassisd[630]: CHASSISD_FRU_UNRESPONSIVE: fpc 2, power on
timeout, retry 1, restarting
Mar 31 05:08:44 bopper chassisd[630]: CHASSISD_FRU_UNRESPONSIVE: fpc 5, power on
timeout, retry 1, restarting
Mar 31 05:10:19 bopper chassisd[630]: CHASSISD_FRU_UNRESPONSIVE: fpc 2, power on
timeout, retry 2, restarting
Mar 31 05:10:26 bopper chassisd[630]: CHASSISD_FRU_UNRESPONSIVE: fpc 5, power on
timeout, retry 2, restarting
Mar 31 05:12:00 bopper chassisd[630]: CHASSISD_FRU_UNRESPONSIVE: fpc 2, power on
timeout, retry 3, restarting
Mar 31 05:12:07 bopper chassisd[630]: CHASSISD_FRU_UNRESPONSIVE: fpc 5, power on
timeout, retry 3, restarting
Mar 31 05:13:41 bopper chassisd[630]: CHASSISD_FRU_UNRESPONSIVE: FPC 2
unresponsive, setting offline!
Mar 31 05:13:48 bopper chassisd[630]: CHASSISD_FRU_UNRESPONSIVE: FPC 5
unresponsive, setting offline!
When an FPC fails, the System and Switch Board (SSB), System Control Board (SCB),
and Switching and Forwarding Modules (SFMs) generate error messages. The
system log file records the time the failure or event occurred, the severity level, a code,
and a message description. Use the
only FPC error messages. Use this information to diagnose an FPC problem and to let
the Juniper Networks Technical Assistance Center (JTAC) know what error messages
were generated and the router events prior to the FPC problem. For more information
about system log messages, see the Junos OS System Log Messages Reference .
To determine the details of the FPC error messages in the Chassis Daemon log file.
To display FPC error messages in the
user@host> show log chassisd | match "fpc | kernel | tnp"
user@host> show log chassisd | match "fpc | kernel | tnp"
Nov 11 15:58:31 m40-2 /kernel: pfe_listener_connect: conn established: listener
idx=0, tnpaddr=2
Nov 11 15:58:42 m40-2 tnp.bootpd[2497]: BOOTPD_BOOTSTRING: Boot string: boot 1
| match
filter command to look for specific
log file:
show log messages | match fpc
log file, use the following command:
chassisd
messages
command to view
Copyright © 2012, Juniper Networks, Inc.