682
The command shuts down the Routing Engine cleanly, so its state information is
preserved.
Wait to continue until all software processes have shut down.
Flip the ends of the extractor clips outward.
6.
Grasp the extractor clips and slide the unit about halfway out of the chassis.
7.
Place one hand under the MCS to support it, slide it completely out of the chassis,
8.
and place it on the antistatic mat or in the electrostatic bag.
Align the rear of the MCS with the guides inside the chassis and slide it in completely.
9.
Press the extractor clips on the left and right sides of the MCS inward.
10.
Verify that the green LED labeled
11.
module LEDs on the craft interface to verify that the green LED labeled
for the host module to which the MCS belongs.
Verify correct MCS functioning by using the
12.
If the replacement MCS works, you can be certain that the replaced MCS failed.
Checklist for Monitoring Redundant MCSs on page 675
OK
on the MCS faceplate is lit. Also check the host
show chassis environment mcs
Copyright © 2012, Juniper Networks, Inc.
is lit
ONLINE
command.