Meaning
Check the System Uptime
Purpose
Action
Sample Output
Meaning
Check the CFEB Connection
Purpose
Action
Perform a Swap Test on the CFEB
Purpose
Copyright © 2012, Juniper Networks, Inc.
Slot 1 information:
State
The command output displays how long the CFEB has been operating. A short uptime
can indicate a CFEB failure. Look for error messages that were generated at least 5
minutes prior to the failure event by using the following command:
user@host> show log messages | match cfeb
To verify CFEB failure by checking the system uptime.
To check the system uptime, use the following command:
user@host> show system uptime
user@host> show system uptime
Current time:
2002-07-17 16:43:45 PDT
System booted:
2002-07-12 17:29:12 PDT (4d 23:14 ago)
Protocols started: 2002-07-12 17:29:56 PDT (4d 23:13 ago)
Last configured:
2002-07-10 23:10:27 PDT (6d 17:33 ago) by regress
4:43PM
up 4 days, 23:15, 2 users, load averages: 0.07, 0.02, 0.00
The command output displays the time when the system was last booted, in days and
hours. If the boot time is short, it can indicate a Routing Engine or a CFEB failure. Look
for error messages that were generated at least 5 minutes prior to the failure event by
using the following command:
user@host> show log messages | match cfeb
Verify CFEB failure by checking the CFEB connection.
Make sure the CFEB is properly seated in the midplane. Check that the thumbscrews on
each CFEB ejector lever are securely tightened. Use a Phillips screwdriver to ensure that
the screws are securely tightened.
To verify CFEB failure by performing a swap test on the CFEB.
CAUTION:
Before performing a swap test, always check for bent pins in the
midplane and check the CFEB for stuck pins in the connector. Pins stuck in
the component connector can damage other good slots during a swap test.