Juniper M Series Monitoring And Troubleshooting Manual page 148

Hide thumbs Also See for M Series:
Table of Contents

Advertisement

M Series and T Series Routers Monitoring and Troubleshooting Guide
104
Table 34: T1600 Router Chassis Component Alarm Conditions (continued)
Chassis
Component
Alarm Condition
FPC
An FPC has an out-of-range
or invalid temperature reading.
An FPC microcode download
has failed.
An FPC has failed. If this
occurs, the FPC attempts to
reboot. If the SCB sees that an
FPC is rebooting too often, it
shuts down the FPC.
Too many hard errors in FPC
memory.
Too many soft errors in FPC
memory.
Hot swapping
Too many hot-swap interrupts
are occurring. This message
generally indicates that a
hardware component that
plugs into the router's
backplane from the front
(generally, an FPC) is broken.
Alarm
Remedy
Severity
Replace the failed FPC.
Yellow
Replace the failed FPC.
Red
Replace the failed FPC.
Red
Replace the failed FPC.
Red
Replace the failed FPC.
Red
-----------------------------------
Red
Copyright © 2012, Juniper Networks, Inc.