Figure 297: T320, T640, and T1600 Router Routing Engines

T320 router rear
RE0
RE1
Related
Documentation
Copyright © 2012, Juniper Networks, Inc.
Routing
Engines
Routing
Engines
Both the Routing Engine and the Control Board must be installed for the host subsystem
to function. When two host subsystems are installed in the router, both are powered on,
but only one is the master; the second host subsystem is the backup and performs no
functions. By default, the master host subsystem has components installed in slots
and
; the backup host module has components installed in slots
CB0
Routing Engine physically fails, the other one assumes the routing functions. If a software
failure occurs, the other backup Routing Engine assumes routing functions if some
preliminary configuration has been done.
The T320 router, T640 router, and T1600 router craft interface LEDs indicate the Routing
Engine operating status and mastership.
Check the T320 Router Routing Engine LEDs on page 187
Check the T640 Router Routing Engine LEDs on page 187
Chapter 29: Monitoring Redundant Routing Engines
T640 router rear
T1600 router rear
RE0
RE1
RE0
RE1
RE0
and
. If one
RE1
CB1
597