Table 83: TX Matrix Router Two-Input 160-A DC Power Supply LEDs

LED
Color
Green
CB OK
CB TRIP
Yellow
OVER TEMP
Yellow
DC OK
Blue
Copyright © 2012, Juniper Networks, Inc.
State
On steadily
Off
On steadily
Off
On steadily
Off
On steadily
Blinking
Off
Table 84 on page 299
describes the functions of the TX Matrix three-input 240-A DC
power supply LEDs.

Table 84: TX Matrix Router Three-Input 240-A DC Power Supply LEDs

LED
Color
—One per
Green
CB ON
input
Chapter 10: Monitoring Power Supplies
Description
Circuit breaker is on.
Circuit breaker is off.
Circuit breaker is not turned on, or host subsystem
has detected a failure and has turned the circuit
breaker off.
No problems have occured with circuit breaker, or
the power supply is off.
Power supply has exceeded recommended
temperature.
Power supply is within the recommended
temperature or is not turned on.
Power supply is installed correctly and is
functioning normally.
Power supply is starting up, is not properly
installed, or is not functioning correctly. One of the
inputs might have failed, or the power supply might
not be receiving sufficient power.
Power supply is not powered on.
State
Description
On steadily
Circuit breaker is on.
Off
Circuit breaker is not turned on, or
host subsystem has detected a
failure and has turned the circuit
breaker off.
299