M Series and T Series Routers Monitoring and Troubleshooting Guide

Display the FEB Environmental Status

Purpose
Action
Sample Output
Meaning

Display the FEB Detailed Status

Purpose
Action
Sample Output
Meaning
Related
Documentation
556
To isolate problems in the FEB by checking the FEB environmental status.
To display the FEB environmental status, use the following command:
user@host> show chassis environment
user@m5-host> show chassis environment
Class Item
Power Power Supply A
Power Supply B
Temp
FPC Slot 0
FEB
PS Intake
PS Exhaust
[...Output truncated...]
The command output displays the temperature and status of the FEB, which can be
Failed
, or
Absent
.
To obtain detailed information about the FEB status.
To display more detailed FEB status, use the following command:
user@host> show chassis feb
user@host> show chassis feb
FEB status:
Temperature
CPU utilization
Interrupt utilization
Heap utilization
Buffer utilization
DRAM
Internet Processor II
Start time
Uptime
The command output displays the temperature of the air passing by the FEB, in degrees
Centigrade. It displays the total percentage of CPU, interrupt, heap space, and buffer
space being used by the FEB processor, including the total DRAM available to the FEB
processor. The command output displays the time when the FEB started running and
how long the FEB has been running. A short uptime can indicate that there is an FEB
problem.
Checklist for Monitoring the FEB on page 553
Status
Measurement
OK
OK
OK
32 degrees C / 89 degrees F
OK
31 degrees C / 87 degrees F
OK
26 degrees C / 78 degrees F
OK
31 degrees C / 87 degrees F
37 Centigrade
0 percent
0 percent
16 percent
43 percent
64 Mbytes
Version 1, Foundry IBM, Part number 9
1999-01-24 16:24:42 UTC
2 hours, 21 minutes, 28 seconds