Display Error Messages in the Messages Log File

Purpose
Action
112
Table 35: TX Matrix and TX Matrix Plus Router Chassis Component Alarm
Conditions (continued)
Chassis
Component
Alarm Condition
Temperature
The chassis temperature
exceeded 55 degrees C, the
fans turned on to full speed,
and one or more fans have
failed.
The chassis temperature
exceeded 65 degrees C and
the fans have been turned on
to full speed.
The chassis temperature
exceeded 65 degrees C and a
fan failed. If this condition
persists for more than 4
minutes, the router shuts
down.
Chassis temperature
exceeded 75 degrees C. If this
condition persists for more
than 4 minutes, the router
shuts down.
The temperature sensor
failed.
To determine the details of the error messages in the Messages Log File.
To display router component error messages in the
following command:
Alarm
Remedy
Severity
Check the room
Yellow
temperature.
Check the air filter
and replace it.
Check the air flow.
Check the fan.
Check the room
Yellow
temperature.
Check the air filter
and replace it.
Check the air flow.
Check the fan.
Check the room
Red
temperature.
Check the air filter
and replace it.
Check the air flow.
Check the fan.
Check the room
Red
temperature.
Check the air filter
and replace it.
Check the air flow.
Check the fan.
For technical support,
Red
open a support case
using the Case Manager
link at
http://www.juniper.net
/support/
or call
1-888-314-JTAC (within
the United States) or
1-408-745-9500
(outside the United
States).