448
4 alarms currently active
Alarm time
2002-05-14 09:23:58 PDT
2002-05-14 09:23:55 PDT
2002-05-14 09:23:53 PDT
2002-05-14 09:20:51 PDT
The command output displays the alarm date, time, severity level, and description.
To determine the details of the SFM error messages in the system log file.
To display the SFM error messages in the system log file, use the following CLI command:
user@host> show log messages
user@host> show log messages
Jun 11 20:31:11 hissy-re0 craftd[556]:
is not forwarding
Jun 11 20:31:11 hissy-re0 alarmd[555]: Alarm set: SFM color=RED, class=CHASSIS,
reason=No SFM Online,
the box is not forwarding
The
system log file records the time the failure or event occurred, the severity
messages
level, a code, and a message description. You can also use the
command to see error messages that are generated when an SFM fails or is offline.
sfm
Use this information to diagnose a power supply problem and to let the Juniper Networks
Technical Assistance Center (JTAC) know what error messages were generated and the
router events that occurred before and after the problem. For more information about
system log messages, see the Junos OS System Log Messages Reference.
To determine the details of the error messages in the chassis daemon log file. The chassis
daemon (
) log file keeps track of the state of each chassis component.
chassisd
To display the SFM error messages logged in the chassis daemon, use the following
command:
user@host> show log chassisd
user@host> show log chassisd
Jun 11 20:50:16 mcs_intr_handler fpm_mcsfd 10
Jun 11 20:50:16 mcs_intr mcs_ints_pending 0x7cbf20 button_status 0x0
Jun 11 20:50:16 bp_handle_button_intr button status 0x0
Jun 11 20:50:16 mcs_intr_handler fpm_mcsfd 10
Jun 11 20:50:16 mcs_intr mcs_ints_pending 0x7cbf20 button_status 0x8
Jun 11 20:50:16 bp_handle_button_intr button status 0x8
Jun 11 20:50:16 mcs_intr_handler fpm_mcsfd 10
Jun 11 20:50:16 mcs_intr mcs_ints_pending 0x7cbf20 button_status 0x8
Class
Description
Major
SFM Failure
Major
SFM Failure
Major
SFM Failure
Major
No SFM Online, the box is not forwarding