TX Matrix Plus Router Redundant Cooling System Components
642
Checklist for Monitoring Redundant Cooling System Components on page 623
The cooling system contains the following components:
Two front fan trays
Rear fan tray
Front and rear air filter
Power supply fans
The cooling system has redundant components, which are controlled by the host
subsystem. If one of the fans fails, the host subsystem increases the speed of the
remaining fans to provide sufficient cooling for the TX Matrix Plus router indefinitely.
Figure 329 on page 642
shows airflow through the TX Matrix Plus router.

Figure 329: TX Matrix Plus Router Cooling System and Airflow

Front view
Airflow (front boards)
Airflow (back boards)
Fan tray
Card cage
Fan tray
Air intake
Figure 330 on page 643
shows the cooling system components in TX Matrix Plus routers.
Rear view
Air exhaust
Card cage
Front
Power
Power
supply
supply
Side view
Airflow (front boards)
Fan tray
Fan tray
Card cage
Card cage
Fan tray
Fan tray
Power
supply