Juniper M Series Monitoring And Troubleshooting Manual page 736

Hide thumbs Also See for M Series:
Table of Contents

Advertisement

M Series and T Series Routers Monitoring and Troubleshooting Guide
Meaning
692
Power PEM 0
PEM 1
Temp
[...Output truncated...]
SPP 0
SPR 0
SPP 1
SPR 1
SPP 2
SPR 2
SFM 3
[...Output truncated...]
The command output displays the status and temperature for the SFM and its two
serialized components: the SPP and SPR cards.
If there is a problem with the SFM status, you can display more detailed environmental
information with the following command:
user@host> show chassis environment sfm
For M40e routers:
SFM 0 status:
State
SPP temperature
SPR temperature
SPP Power:
1.5 V
2.5 V
3.3 V
5.0 V
5.0 V bias
SPR Power:
1.5 V
2.5 V
3.3 V
5.0 V
5.0 V bias
8.0 V bias
CMB Revision
SFM 1 status:
State
SPP temperature
SPR temperature
SPP Power:
1.5 V
2.5 V
3.3 V
5.0 V
5.0 V bias
SPR Power:
1.5 V
2.5 V
3.3 V
5.0 V
5.0 V bias
8.0 V bias
CMB Revision
For M160 routers:
OK
OK
OK
37 degrees C / 98 degrees F
OK
46 degrees C / 114 degrees F
OK
38 degrees C / 100 degrees F
OK
48 degrees C / 118 degrees F
OK
39 degrees C / 102 degrees F
OK
54 degrees C / 129 degrees F
Offline
Online
37 degrees C / 98 degrees F
41 degrees C / 105 degrees F
1501 mV
2495 mV
3293 mV
5042 mV
4998 mV
1504 mV
2499 mV
3297 mV
5050 mV
5008 mV
8288 mV
12
Online - Standby
41 degrees C / 105 degrees F
40 degrees C / 104 degrees F
1498 mV
2468 mV
3296 mV
5042 mV
4993 mV
1496 mV
2471 mV
3299 mV
5037 mV
4996 mV
8266 mV
12
Copyright © 2012, Juniper Networks, Inc.

Advertisement

Table of Contents
loading

This manual is also suitable for:

T series