M Series and T Series Routers Monitoring and Troubleshooting Guide
106
Table 34: T1600 Router Chassis Component Alarm Conditions (continued)
Chassis
Component
Alarm Condition
SCG
A backup SCG is offline.
An SCG has an out-of-range
or invalid temperature reading.
An SCG was removed.
All SCGs are offline or missing.
An SCG failed.
SIB
A spare SIB is missing.
A SIB failed.
A spare SIB failed.
A SIB has an out-of-range or
invalid temperature reading.
A SIB is missing.
A SIB failed.
SPMB
A local SPMB is offline.
Alarm
Remedy
Severity
Set the backup SCG
Yellow
online.
Replace the failed SCG.
Yellow
Insert an SCG into an
Yellow
empty slot.
Insert SCGs into empty
Red
slots or set all SCGs
online.
Replace the failed SCG.
Red
Insert a spare SIB into
Yellow
an empty slot.
Replace the failed SIB.
Yellow
Replace the failed SIB.
Yellow
Replace the failed SIB.
Yellow
Insert a SIB into empty
Red
slot.
Replace the failed SIB.
Red
Reset the Control
Red
Board. If this fails,
replace the Control
Board.