Juniper M Series Monitoring And Troubleshooting Manual page 122

Hide thumbs Also See for M Series:
Table of Contents

Advertisement

M Series and T Series Routers Monitoring and Troubleshooting Guide
78
Table 28: M40 Router Chassis Component Alarm Conditions (continued)
Chassis
Component
Alarm Condition
Power supplies
A power supply was removed
from the chassis.
A power supply temperature
sensor failed.
A power supply fan failed.
A power supply has high
temperature.
A 5V power supply has failed.
A 3.3V power supply failed.
A 2.5V power supply failed.
A power supply input failed.
A power supply has failed.
Remedy
Insert a power supply into
an empty slot.
Replace the failed power
supply or power entry
module.
Replace the failed power
supply fan.
Replace the failed power
supply or power entry
module.
Replace the failed power
supply or power entry
module.
Replace the failed power
supply or power entry
module.
Replace the failed power
supply or power entry
module.
Check the power supply
input connection.
Replace the failed power
supply or power entry
module.
Copyright © 2012, Juniper Networks, Inc.
Alarm
Severity
Yellow
Yellow
Yellow
Red
Red
Red
Red
Red
Red

Advertisement

Table of Contents
loading

This manual is also suitable for:

T series

Table of Contents