Display M40E Router Redundant Sfm Mastership; Display Sfm Mastership At The Command Line - Juniper M Series Monitoring And Troubleshooting Manual

Hide thumbs Also See for M Series:
Table of Contents

Advertisement

Related
Documentation

Display M40e Router Redundant SFM Mastership

Display SFM Mastership at the Command Line

Purpose
Action
Sample Output
Copyright © 2012, Juniper Networks, Inc.
SFM 0 status:
State
SPP temperature
SPR temperature
SPP Power:
1.5 V
2.5 V
3.3 V
5.0 V
5.0 V bias
SPR Power:
1.5 V
2.5 V
3.3 V
5.0 V
5.0 V bias
8.0 V bias
CMB Revision
SFM 1 status:
[...Output truncated...]
SFM 2 status:
[...Output truncated...]
SFM 3 status:
State
- Hard FPC error
[...Output truncated...]
The command output displays the SFM slot, status, and the temperature of the air flowing
past the SPP and SPR cards. It also displays information about the SFM power supplies.
The chassis management bus (CMB) backup revision level is also displayed.
You can display the environmental status of a particular SFM with the following command:
user@host> show chassis environment sfm slot
Monitoring Redundant SFMs on page 683
(For M40e routers only) To display which SFM is master:
Display SFM Mastership at the Command Line on page 693
1.
Display SFM Mastership Information from the Craft Interface on page 694
2.
To determine the SFM mastership at the command line.
To display the SFM summary status at the command line, use the following CLI command:
user@host> show chassis sfm
For M40e routers:
Chapter 36: Monitoring Redundant SFMs
Online
36 degrees C / 96 degrees F
45 degrees C / 113 degrees F
1501 mV
2485 mV
3291 mV
5020 mV
4974 mV
1501 mV
2492 mV
3301 mV
5028 mV
4986 mV
8305 mV
12
Offline
693

Advertisement

Table of Contents
loading

This manual is also suitable for:

T series

Table of Contents