Table 23: Alarms For Jrr200 Route Reflector Chassis Components - Juniper JRR200 Hardware Manual

Route reflector
Hide thumbs Also See for JRR200:
Table of Contents

Advertisement

JRR200 Route Reflector Hardware Guide

Table 23: Alarms for JRR200 Route Reflector Chassis Components

Component
Fan
66
Alarm Conditions
At least one of the fans have
failed.
The JRR200 route reflector
chassis temperature is too
warm.
Missing fan tray
Fan over-speeding
Fan spinning below its speed
Impeding fan failure
Action
Check and adjust the room
temperature, if possible.
Check the air flow and ensure
that the airflow through JRR200
route reflector is unobstructed.
Replace the failed fan tray to
avoid failure of the other fan
trays.
Open a support case using the
Case Manager link at
https://www.juniper.net/support/
or call 1-888-314-5822 (toll-free
within the United States and
Canada) or 1-408-745-9500
(from outside the United States).
Check the room temperature.
Check the air flow.
Run all the Fans at full speed.
Open a support case using the
Case Manager link at
https://www.juniper.net/support/
or call 1-888-314-5822 (toll-free
within the United States and
Canada) or 1-408-745-9500
(from outside the United States).
Install the missing fan tray.
Check if the fan is spinning more
than the configured speed.
Replace the fan tray as it is likely
to fail.
Check if the fan is spinning below
the configured speed.
Replace the fan tray as it is likely
to fail.
Replace the fan tray.
Copyright © 2018, Juniper Networks, Inc.
Alarm Severity
Steady red (major)
Yellow (minor)/Red
(major)
Red (major)
Yellow (minor)
Yellow (minor)
Yellow (minor)