M Series and T Series Routers Monitoring and Troubleshooting Guide
Related
Documentation
Switch Control Board Mastership
Related
Documentation
Check the Control Board Alarms
Purpose
Action
Related
Documentation
Replace a Control Board
672
Table 150: Control Board LEDs
Label
Color
Green
OK
FAIL
Amber
MASTER
Blue
Checklist for Monitoring Redundant Control Boards on page 665
To switch the Control Board master to backup or the Control Board backup to master,
take the Control Board offline by pressing the Control Board offline button on the
component faceplate. The backup Control Board will automatically start up. To remove
the Control Board, see
"Replace a Control Board" on page
Checklist for Monitoring Redundant Control Boards on page 665
To determine the details of the Control Board alarms.
To check for the Control Board alarms, see
page
390. For conditions that trigger Control Board alarms, see
Alarms" on page
67.
Checklist for Monitoring Redundant Control Boards on page 665
The Control Board can fail and not start, or it can cause a connectivity problem between
the Routing Engine and the Packet Forwarding Engine components. You can perform a
swap test on the Control Board to try to pinpoint the problem.
To replace a Control Board, see
CAUTION:
Before performing a swap test, always check for bent pins in the
midplane and check the Control Board for stuck pins in the connector. Pins
stuck in the component connector can damage other good slots during a
swap test.
State
Description
On steadily
Control Board is online and is
functioning normally.
On steadily
Control Board has failed.
On steadily
Control Board is functioning as master.
"Checking the Control Board Alarms" on
"Perform a Control Board Swap Test" on page
Copyright © 2012, Juniper Networks, Inc.
672.