Sample Output - Juniper M Series Monitoring And Troubleshooting Manual

Hide thumbs Also See for M Series:
Table of Contents

Advertisement

Sample Output

Meaning
Copyright © 2012, Juniper Networks, Inc.
user@host>show chassis environment
T640@host>show chassis environment
Class
Item
Temp
PEM 0
PEM 1
SCG 0
SCG 1
Routing Engine 0
Routing Engine 1
CB 0
SIB 0
SIB 1
SIB 2
SIB 3
SIB 4
[...Output truncated...]
The command output displays each component installed in the router, including the
operating status and temperature.
If there is a problem with the SIB status, you can display more detailed environmental
information with the following command:
user@host>show chassis environment sib
user@host> show chassis environment sib
SIB 0 status:
State
Temperature
Power:
GROUND
1.8 V
2.5 V
3.3 V
1.8 V bias
3.3 V bias
5.0 V bias
8.0 V bias
SIB 1 status:
State
Temperature
Power:
GROUND
1.8 V
2.5 V
3.3 V
1.8 V bias
3.3 V bias
5.0 V bias
8.0 V bias
SIB 2 status:
[...Output truncated...]
SIB 3 status:
[...Output truncated...]
SIB 4 status:
[...Output truncated...]
Status
Measurement
Absent
OK
32 degrees C / 89 degrees F
OK
37 degrees C / 98 degrees F
Absent
OK
35 degrees C / 95 degrees F
Absent
OK
36 degrees C / 96 degrees F
OK
44 degrees C / 111 degrees F
OK
50 degrees C / 122 degrees F
OK
50 degrees C / 122 degrees F
OK
50 degrees C / 122 degrees F
OK
52 degrees C / 125 degrees F
Spare
44 degrees C / 111 degrees F
0 mV
1807 mV
2478 mV
3308 mV
1797 mV
3284 mV
5018 mV
7440 mV
Online
50
degrees C / 122 degrees F
0 mV
1814 mV
2485 mV
3321 mV
1794 mV
3313 mV
5028 mV
7553 mV
Chapter 16: Monitoring the SIBs
423