19.  Periodical maintenance procedure FS-533
NOTE
▪ The alcohol described in the cleaning procedure of maintenance represents the isopropyl alcohol.
19.1  Paper exit section
19.1.1  Cleaning procedure for each parts
(1)  Periodically cleaning parts/cycle
• Each rollers/Each rolls: Every 300,000 counts
(2)  Cleaning point
NOTE
▪ Do not clean the alignment roller F/R.
19.1.2  Cleaning the paper exit paddle
(1)  Periodically cleaning parts/cycle
• Paper exit paddle: Every 300,000 counts
(2)  Procedure
[1]
19.2  Alignment section
19.2.1  Replacing the alignment roller assy F/R
(1)  Periodically replacing parts/cycle
• Alignment roller assy F/R: Every 1,000,000 counts
[1]
[2]
[1]
Alignment roller assy R
(2)  Removal procedure
1. Remove the front cover.
F PERIODICAL MAINTENANCE > 19. Periodical maintenance procedure FS-533
1. Using a cleaning pad dampened with alcohol, wipe the paper exit paddle [1].
[2]
Alignment roller assy F