Konica Minolta bizhub C658 Service Manual page 887

Hide thumbs Also See for bizhub C658:
Table of Contents

Advertisement

bizhub C658/C558/C458/C368/C308/C258
1. Select [Service Mode] -> [CS Remote Care] -> [Maintenance/Default Settings], and touch [Detail Setting].
2. Touch [Basic Setting] -> [Device ID], and input Device ID (13 digits).
NOTE
▪ [Device ID] displays the serial number that is entered in [Service Mode] -> [System 1] -> [Serial Number].
10.
Setting the telephone number of the Center
1. Select [Service Mode] -> [CS Remote Care] -> [Maintenance/Default Settings], and touch [Detail Setting].
2. Touch [Basic Setting] -> [Center Telephone Number].
3. Input the telephone number of the center using the 10-key pad and [P], [T], [W], [-].
11.
Inputting the device telephone number
1. Select [Service Mode] -> [CS Remote Care] -> [Maintenance/Default Settings], and touch [Detail Setting].
2. Touch [Basic Setting] -> [Device Telephone Number].
3. Input the Device telephone number using the10-key pad and [P], [T], [W], [-].
12.
Inputting the AT command for initializing the modem
1. Select [Service Mode] -> [CS Remote Care] -> [Maintenance/Default Settings], and touch [Detail Setting].
2. Touch [AT Command].
3. Input AT Command.
NOTE
▪ Change this command only when it is necessary. (They do not need to be changed in normal condition.)
▪ For details on AT command, see the manual for the modem.
13.
Setting the Software SW for CS Remote Care
NOTE
▪ This setting is not normally necessary. Take this step only when necessary in a specific connecting condition.
14.
Executing the initial transmission
1. Select [Service Mode] -> [CS Remote Care] -> [Maintenance/Default Settings], and touch [Detail Setting].
2. Touch [Basic Setting] -> [Initial Transmission].
3. Touch [initial transmission] key on the right bottom of the screen to start initial transmission.
4. When the machine is properly connected with the center, CS Remote Care setting screen will be displayed.
NOTE
▪ The initial transmission key at the right bottom of the screen will be displayed only when the center ID, the device ID,
Telephone number of the center and the device telephone number have been input.
However, if an invalid value is input as the device ID, the initial transmission key is not displayed.
5.8.2  Using the Fax line modem
NOTE
▪ Setting will be available only when the optional fax board is installed.
1. Register the device ID
• Register the device ID to the application at CS Remote Care center.
NOTE
• The initial connection is not available unless the device ID is registered.
2. Remove the telephone line modem
• Be sure to remove the telephone line modem when the fax line is used.
3. Inputting the ID code
1. Select [Service Mode] -> [CS Remote Care] -> [Maintenance/Default Settings], and touch [ID Code].
2. Input the seven digits ID of the service person, and touch [ID Code] again.
4.
Clearing the RAM
1. Select [Service Mode] -> [CS Remote Care] -> [Maintenance/Default Settings], and touch [Detail Setting].
2. Touch [RAM Clear].
3. Select [Set], and touch [OK].
5. Selecting the CS Remote Care function
• Select [Service Mode] -> [CS Remote Care] -> [Maintenance/Default Settings] -> [System Setting], and touch [Fax].
6. Inputting the ID code
1. Select [Service Mode] -> [CS Remote Care] -> [Maintenance/Default Settings], and touch [ID Code].
2. Input the seven digits ID of the service person, and touch [ID Code] again.
7.
Setting the date and time for CS Remote Care
1. Select [Service Mode] -> [CS Remote Care] -> [Maintenance/Default Settings], and touch [Detail Setting].
2. Touch [Date & Time Setting].
3. Input the date, time and the time zone using the 10-key pad, and touch [Set].
8.
Setting the Center ID
1. Select [Service Mode] -> [CS Remote Care] -> [Maintenance/Default Settings], and touch [Detail Setting].
2. Touch [Basic Setting] -> [Center ID], and input the Center ID (five digits).
9.
Confirm the Device ID
1. Select [Service Mode] -> [CS Remote Care] -> [Maintenance/Default Settings], and touch [Detail Setting].
2. Touch [Basic Setting] -> [Device ID], and input Device ID (13 digits).
NOTE
▪ [Device ID] displays the serial number that is entered in [Service Mode] -> [System 1] -> [Serial Number].
10.
Setting the telephone number of the Center
1. Select [Service Mode] -> [CS Remote Care] -> [Maintenance/Default Settings], and touch [Detail Setting].
2. Touch [Basic Setting] -> [Center Telephone Number].
3. Input the telephone number of the center using the 10-key pad and [P], [T], [W], [-].
11.
Inputting the device telephone number
1. Select [Service Mode] -> [CS Remote Care] -> [Maintenance/Default Settings], and touch [Detail Setting].
2. Touch [Basic Setting] -> [Device Telephone Number].
3. Input the Device telephone number using the10-key pad and [P], [T], [W], [-].
12.
Setting the Software SW for CS Remote Care
NOTE
▪ This setting is not normally necessary. Take this step only when necessary in a specific connecting condition.
13.
Executing the initial transmission
I ADJUSTMENT/SETTING > 5. SERVICE MODE