Manual Operation
(Home Return)

11.1 Types of Home Return

The home return is a function to move a position to the origin of a reference position and set
the coordinate to zero. The following ten home return methods are available for FP7 MC Unit.
(CCW)
(-) side
Ball screw
 
Over limit switch (-)
Type of return
Reference position origin
DOG method 1
Home (Z phase), based on front end
DOG method 2
Near home input (HOME), based on
front end
DOG method 3
Home (Z phase), based on back end
DOG method 4
Near home input (HOME), based on
back end
Limit method 1
Home (Z phase), based on front end
Limit method 2
Edge detection of limit switch
Phase Z method
Edge detection of home (Z phase)
Stop-on-contact
Based on stop-on-contact
method 1
Stop-on-contact
Stop-on-contact + Z phase, based on
method 2
front
Data set method
-
11-2
Reverse
Near home input
(HOME)
Operation overview
The leading edge of the first home position (Z
phase) is set as a home position after the
detection of the leading edge of a near home
input (HOME).
The leading edge of a near home input (HOME)
is detected and it is set as a home position.
The leading edge of the first home position (Z
phase) in the home return direction set as a
home position after the detection of a trailing
edge (back end) of the near home input (HOME).
The trailing edge (back end) of a near home input
(HOME) is detected and it is set as a home
position.
Reverses after detecting the leading edge of the
limit switch on the opposite side of the home
return direction. After that, the operation stops at
the first leading edge of the home position (Z
phase). It is set as a home position.
Detects the leading edge of the limit switch in the
home return direction and stops. It is set as a
home position.
Moves the current position to the home return
direction, and stops at the position where the
leading edge of the first home position (Z phase)
is detected. It is set as a home position.
Stops by a mechanical stopping mechanism as a
stopper. A position when a constant time elapses
at a torque value larger than a specified value is
set as a home position.
Although the operation is similar to the stop-on-
contact method, the first position where the Z
phase is detected is set as a home position by
performing the reverse operation after the stop by
a stopper.
The current value is set as a home position.
Forward
(CW)
(+) side
Over limit switch (+)