Panasonic AFP7MC16EC User Manual page 466

Fp7 series. motion control unit
Hide thumbs Also See for AFP7MC16EC:
Table of Contents

Advertisement

Specifications
16.7.4.1 Control Area for Buffer Control
This area is used for reading or writing positioning data by user programs.
Unit
Buffer no.
memory
no. (Hex)
1
UM 06240
1
UM 06241
1
UM 06242
1
UM 06243
1
UM 06244
1
UM 06245
16-70
Name
Default Description
Write data to this area for sending/receiving data of
buffers for positioning data. After the completion of
the execution, it is rewritten to H0 by FP7 MC Unit.
Request
H0
flag control
H0000: No request
H0001: Request
Any other settings will be errors.
Set the request code of data control of buffer for
positioning data.
Request
H0
H0080: Read request
code control
H0081: Write request
Any other settings will be errors.
Stores the response code for the request of the
buffer for positioning data.
Response
H0
H0000: Complete
code control
H0001: In progress
HFF00: Setting value error
Specify the axis number of positioning data to be
transferred.
Axis
Range
number
U1
1-64
control
65-96
Any other settings will be errors.
Specify the starting table number of positioning data
Starting
to be transferred.
table
U1
Range: 1 to 1000
number
Any other settings will be errors.
Specify the table size of positioning data to be
transferred.
Table size
U1
Range: 1 to 500
Any other settings will be errors.
●: Available, -: Not available
Corresponding axis no.
Corresponds to the existing axes 1 to 64.
Corresponds to the virtual axes 1 to 32.
R
W
-