The unit memories used for the extended tables are as follows.
Buffer control area for positioning data
Unit
Buffer
memory
Name
no.
no. (Hex)
Buffer 1
UM 06246
Buffer 2
UM 0A0CE
Extended
:
:
positioning
Buffer 12 UM 3121E
table usage
setting
:
:
Buffer 24 UM 6007E
Buffer 1
UM 06247
Extended
Buffer 2
UM 0A0CF
positioning
:
:
table usage
setting
Buffer 12 UM 3121F
corresponding
:
:
axis no.
Buffer 24 UM 6007F
(Note): for details of the unit memory numbers of each buffer, refer to "16.7.4 Configuration of Positioning Data
Setting Area".
Default Description
Set whether to use the extended positioning table or not.
bit
Name
Extended positioning
15-0
H0
table usage setting
* When using the extended positioning table;
table nos. 401 to 500 is used as extended table nos. 10,001 to
10,100.
Set transfer axis numbers of positioning data.
Range
U0
1 to 64
65 to 96
Any other settings will be errors.
8.10 Use of Extended Positioning Table
Description
0: Not make the table setting
1: Make the table setting
Any other settings will be errors.
Corresponding axis no.
Corresponds to the existing axes 1 to 64.
Corresponds to the virtual axes 1 to 32.
8-57