Automatic Operation (Synchronous Control)
The parameters used for the cam pattern editing with user programs are as follows.
Unit
Axis
memory
Name
no.
no. (Hex)
Cam
-
UM 66F40
pattern
no.
Reserved
-
UM 66F41
for system
No. of
cam
-
UM 66F42
pattern
setting
sections
Shift
-
UM 66F43
amount
9-38
Default Unit
Setting range and description
When reading: Set a cam pattern number to be read out.
When rewriting: Set a cam pattern number to be written.
bit
U0
15-0
Any other settings will be errors.
-
-
When reading, the number of setting sections of the read cam
pattern table is stored.
When rewriting, the cam curve number of the rewritten cam
pattern table is set.
U0
Section
bit
15-0
When reading, the shift amount of the read cam pattern table
is stored.
When rewriting, the shift amount of the rewritten cam pattern
table is stored.
U0
0.01%
bit
15-0
Setting range
Pattern resolution
Axis 16
1024,2048,4096,8192
1 to 64
16384
1 to 32
32768
1 to 16
Name
Description
No. of cam
Setting range: 1 to 20 (sections)
pattern setting
Any other settings will be errors.
sections
Name
Description
Range: 0 to 100.00 (%)
Shift amount
Any other settings will be errors.
Axis 32
Axis 64
1 to
1 to
128
256
1 to
1 to 64
128
1 to 32
1 to 64