Panasonic AFP7MC16EC User Manual page 246

Fp7 series. motion control unit
Hide thumbs Also See for AFP7MC16EC:
Table of Contents

Advertisement

Automatic Operation (Synchronous Control)
 Setting with tool software
Set in the synchronous control setting dialog box.
Parameter name
Advance angle
correction operation
setting
Advance angle
correction
reference amount
Advance angle
correction
reference speed
Advance angle
correction
parameter change
time
 Setting with user programs
The following example shows the case that the advance angle correction reference amount of
1st axis is changed to 50 and the advance angle correction reference speed to 3000.
R0
DF
R1
DF
9-54
Overview
Select the use or non-use of the advance angle correction function.
When using the advance angle correction function, set the correction reference amount
used by FP7 MC Unit for calculating the advance angle correction amount.
The unit follows the unit system of the master axis.
Setting range: -2147483648 to 2147483647 (The decimal point position is based on
unit systems.)
When using the advance angle correction function, set the reference speed used by
FP7 MC Unit for calculating the advance angle correction amount.
The unit follows the unit system of the master axis.
Setting range: 1 to 2147483647 (The decimal point position is based on unit systems.)
Set the time required until a changed value is reflected when the parameter related to
the advance angle correction is changed during the electronic cam operation.
Setting range: 1 to 10000 ms
MV.SL
MV.SL
K50
S1:UM63F96
K3000
S1:UM63F98

Advertisement

Table of Contents
loading

This manual is also suitable for:

Afp7mc32ecAfp7mc64ec

Table of Contents