CMTimeChart Monitor
4. Confirm if the presence/absence of logging data flag is on.
5. Select "Online" > "Stop Logging" from the menu bar.
A confirmation message appears.
6. Press the [OK] button.
The logging operation stops and a confirmation message are displayed.
7. Press the [OK] button.
Then upload the logging data on "CMTimeChart". It can be displayed in the time
chart.
KEY POINTS
When the trigger mode is "Auto", pressing the [OK] button in step 3 turns
on the logging flag. Also, executing the logging stop after step 5 turns on
the presence/absence of logging data flag. For information on the difference
between operations according the trigger modes, refer to "14.5.3 Logging
Operation Diagram".