CMTimeChart Monitor

14.6.2 Settings for Time Chart Display Area

The display of "CMTimeChart" can be adjusted in the Display Setting dialog box. Selecting
"View" > "View Setting..." opens the Display Setting dialog box.
 Display Setting dialog box (Common tab)
Item
No. of
Displayed
Grids
X-axis
No. of Data
Setting
per Grid
Time Scale
Unit Type
No. of
Displayed
Y-axis
Grids
Setting
No. of Whole
Grids
Color Setting
Trigger Setting
14-22
Description
Set the number of grids of a displayed chart in the logging monitor.
Range: 10 to 1,000
(Example) When setting 10, it is divided into 10 by grids.
Set the number of data dividing the area between grids.
Range: 1 to 100
(Example) No. of Data per Grid: 10
(Set the time rate of one grid regarding one is equal to a time scale.)
Set the time scale unit of a displayed chart.
Microsecond / msec / sec / min / hours
Set the number of grids displayed in a displayed chart in the logging monitor.
Range: 10 to 50
Set the total number of grids displayed in the logging monitor.
Set display colors.
Select a trigger number to be displayed. Range: 1 to 16