Manual Operation
(Home Return)
11.3.2 Precautions on Programming
Precautions on programming
• If any value such as a home return setting code, acceleration time, deceleration time, target
speed or creep sped is out of the specified range, a setting value error occurs at the time of
startup.
• For the home return methods which are based on the home position (Z phase) (i.e. DOG
method 1, DOG method 3, Limit method 1, Z phase method and Stop-on-contact method 2),
the operation after shifting to the creep speed is controlled by servo amplifier. Therefore, the
stop request made by FP7 MC Unit is invalid.
• Unit memory numbers allocated to flags and start requests vary depending on axis numbers.
• The specified slot number varies depending on the installation position of the unit.
Operation at Over limit input (Limit is valid)
Condition
Direction
Forward
When Home return
operation is
executed
Reverse
Forward
During Home
return operation
Reverse
11-14
Limit status
Over limit input (+): ON
Over limit input (-): ON
Over limit input (+): ON
Over limit input (-): ON
Over limit input (+): ON
Over limit input (-): ON
Operation
Executable
Executable
Executable
Executable
Automatic reverse operation
Automatic reverse operation