Unit
Axis no.
memory
no. (Hex)
UM 0328E
1
-UM 0328F
UM 03290
1
-UM 032BF
Name
Default
Home
K0
coordinates
Reserved for
-
system
16.7 Unit Memories (Each Axis Setting Area)
Description
Set the home coordinates to be set after the
completion of the home return.
Range: -2,147,483,648 to 2,147,483,647
The ranges vary depending on the unit settings as
below.
pulse: -2,147,483,648 to 2,147,483,647 pulses
μm (0.1 μm): -214,748,364.8 to 214,748,364.7 μm
μm (1 μm): -2,147,483,648 to 2,147,483,647 μm
inch (0.00001 inch) : -21,474.83648 to
21,474.83647 inch
inch (0.0001 inch) : -214,748.3648 to 214,748.3647
inch
degree (0.1 degree): -214,748,364.8 to
214,748,364.7 degrees
degree (1 degree): -2,147,483,648 to
2,147,483,647 degrees
Example) When the unit is μm (0.1 μm), set to
"10000" for making it be 1000.0 μm.
-
●: Available, -: Not available