5.4.2 Cam Pattern Setting
Make electronic cam settings in the case of using an electronic cam. Necessary parameters
are assigned using CMI. The following procedure is explained on the condition that CMI has
already started. The cam pattern setting is made for the cam pattern operation for slave axes.
PROCEDURE
1. Select "Parameter" > "Cam pattern settings" from the menu bar.
The cam pattern settings dialog box is displayed.
2. Set necessary parameters in accordance with the intended use.
KEY POINTS
•
The saved parameter information can be read on CMI.
•
In the case of synchronous control, it also operates according to the
parameters specified in "5.2 Axis Parameter Settings".