The state confirmation areas of the ENI file registration by the node address setting and node
addresses on the network are as follows.
Unit
Node
memory
no.
no. (Hex)
Node
UM 00122
1-16
Node
UM 00123
17-32
Node
UM 00124
33-48
Node
UM 00125
49-64
Node
UM 00126
65-80
Node
UM 00127
81-96
Node
UM 00128
97-112
Node
UM 00129
113-128
Node
UM 0012A
129-144
Node
UM 0012B
145-160
Node
UM 0012C
161-176
Node
UM 0012D
177-192
(Note 1): Sixteen node numbers are allocated to each area (1 word).
bit no. 15
8 7
● ● ● ● ●
Node no.
16
9
● ● ● ● ●
32
25
● ● ● ● ●
48
41
● ● ● ● ●
64
57
● ● ● ● ●
80
73
● ● ● ● ●
96
89
● ● ● ● ●
112
105
● ● ● ● ●
128
121
● ● ● ● ●
144
137
● ● ● ● ●
160
153
● ● ● ● ●
176
169
● ● ● ● ●
192
185
Name
Default Setting range and description
Normal slave
H0
table
0
● ● ● ● ●
8
1
● ● ● ● ●
24
17
● ● ● ● ●
40
33
● ● ● ● ●
56
49
● ● ● ● ●
72
65
● ● ● ● ●
88
81
● ● ● ● ●
104
97
● ● ● ● ●
120
113
● ● ● ● ●
136
129
● ● ● ● ●
152
145
● ● ● ● ●
168
161
● ● ● ● ●
184
177
3.1 Setting of Node Address (ID)
The bits corresponding to normal station addresses among
slaves participating in the network registered in the ENI file turn
on.
bit
Node no.
0
Node 1+16n
1
Node 2+16n
2
Node 3+16n
3
Node 4+16n
4
Node 5+16n
5
Node 6+16n
6
Node 7+16n
7
Node 8+16n
8
Node 9+16n
9
Node 10+16n
10
Node 11+16n
11
Node 12+16n
12
Node 13+16n
13
Node 14+16n
14
Node 15+16n
15
Node 16+16n
3-9

Advertisement