16.7.2 Configuration of Parameter Setting Area

Whole unit memory map
UM 00000
System area
128 words
UM 0007F
UM 00080
Input control area
256 words
UM 0017F
UM 00180
Output control area
256 words
UM 0027F
UM 00280
Common area
9,104 words
UM 0260F
UM 02610
System area
48 words
UM 0263F
UM 02640
Each axis
information area
3,072 words
UM 0323F
UM 03240
Each axis setting area
396,480 words
UM 63EFF
UM 63F00
System area
64 words
UM 63F3F
UM 63F40
Synchronous
control setting area
10,752 words
UM 6693F
UM 66940
Positioning operation
change setting area
1,536 words
UM 66F3F
UM 66F40
Cam pattern editing
area
106 words
UM 66FA9
UM 03240
Parameter setting area
12,288 words
UM 0623F
UM 06240
Positioning data
setting area
384,192 words
UM 63EFF
16.7 Unit Memories (Each Axis Setting Area)
Starting no. Name
UM 03240
Parameter setting area of 1st axis
UM 032C0
Parameter setting area of 2nd axis
UM 039C0
Parameter setting area of 16th axis
UM 041C0
Parameter setting area of 32th axis
UM 049C0
Parameter setting area of 48th axis
UM 051C0
Parameter setting area of 64th axis
Parameter setting area of virtual
UM 05240
1st axis
Parameter setting area of virtual
UM 059C0
16th axis
Parameter setting area of virtual
UM 061C0
32th axis
No. of words
128 words
128 words
128 words
:
:
128 words
:
:
128 words
:
:
128 words
128 words
:
:
128 words
:
:
128 words