FIP-1. 78 CRUM ID 093-965

Step
Possible causative parts:
PHD ASSY (PL4.1.21)
PWBA MCU (PL8.2.13)
HARN ASSY PHD XPRO (PL9.1.11)
Does the error still occur when the power is turned OFF and
1
ON?
Checking the PHD ASSY type
2
Is the seated PHD ASSY for 1320c?
Does the error still occur when the power is turned OFF and
3
ON?
Checking after reseating the PHD ASSY
Reseat the PHD ASSY.
4
Does the error still occur when the power is turned OFF and
ON?
Checking the connectors for connection
Check the connectors between the PWBA MCU and PHD
5
ASSY.
Are P/J42 and P/J422 connected correctly?
Does the error still occur when the power is turned OFF and
6
ON?
Checking the HARN ASSY PHD XPRO for continuity
Disconnect P422 from the PHD ASSY.
Disconnect J42 from the PWBA MCU.
Is each cable of P422 <=> J42 continuous?
7
Checking after replacing the PHD ASSY
Replace the PHD ASSY. (Refer to Removal 4/Replacement
8
50.)
Does the error still occur when the power is turned OFF and
ON?
Check
1 - 296
Chapter 1 Troubleshooting
Remedy
Yes
Go to step 2.
End of work.
Replace the PHD
Go to step 4.
ASY for 1320c,
then go to step 3.
Go to step 4.
End of work.
Go to step 5.
End of work.
Reconnect the
connector(s) P/
Go to step 7.
J42 and/or P/J422
surly, then go to
step 6.
Go to step 7.
End of work.
Replace the
Go to step 8.
HARN ASSY PHD
XPRO.
Replace the
PWBA MCU.
(Refer to Removal
End of work.
43/ Replacement
11.)