Flows 60 Insert PHD 091-972
Does the error still occur when the
power is turned OFF and ON?
Yes
Checking after reseating the PHD
ASSY
Reseat the PHD ASSY.
Does the error still occur when the
power is turned off and on?
Yes
Checking after replacing the PHD ASSY
Replace the PHD ASSY. (Refer to
Removal 4/Replacement 50.)
CAUTION: Be sure to pull eight sealing
tapes out from a new PHD ASSY before
installation.
Does the error still occur when the
power is turned off and on?
Yes
Replace the PWBA MCU. (Refer to
Removal 43/ Replacement 11.)
No
No
No
1 - 106
Chapter 1 Troubleshooting
END
END
END